To select explosion-proof equipment, first identify the hazardous area classification where the equipment will operate, then match its certification and protection marking to the site’s gas or dust hazard, zone or division, and temperature requirements. A product described as “explosion-proof” is not automatically suitable for every hazardous location. For an explosion-proof borescope, check the markings and documentation for the complete instrument configuration—including the probe, display or hand unit, battery, and any accessories used in the classified area. Confirm the final selection with your site safety team or a qualified classification professional.
At Coantec, we recommend starting with the area classification documents rather than a product name or a general request for an Ex instrument. This helps buyers communicate the actual operating conditions and assess whether a borescope is appropriate for the inspection task. The information below explains the core classification concepts, the details to collect, and the questions to ask a supplier.
Area classification identifies locations where a flammable gas, vapor, mist, or combustible dust may be present in a quantity that requires controls for ignition sources. The classification is based on the substance and how often, or for how long, an explosive atmosphere may occur. It is typically determined through a site-specific assessment and documented in drawings or other engineering records. Equipment selection should follow that documentation and the regulations applicable to the installation.
IEC-based systems commonly classify gas or vapor hazards as Zones 0, 1, and 2, and combustible-dust hazards as Zones 20, 21, and 22. In broad terms, the lower zone number indicates a greater likelihood or duration of an explosive atmosphere: Zone 0 and Zone 20 describe conditions that may occur continuously, frequently, or for long periods, while Zone 2 and Zone 22 describe conditions that are not likely in normal operation and, if they occur, are expected to be brief. The exact definitions and equipment requirements depend on the applicable standards and jurisdiction.
Some North American systems use Class, Division, and Group designations. Class identifies the general type of hazardous material, Division describes the likelihood of its presence under specified conditions, and Group identifies material characteristics relevant to equipment selection. Zone and Division classifications are related ways of describing hazards, but they are not interchangeable labels; use the system recognized by the site and its authority having jurisdiction.
Classification is more than a zone or division. Buyers also need to know the hazardous substance group and the maximum surface temperature permitted for the process environment. For reference, commonly used IEC temperature classes specify maximum equipment surface temperatures of 450 °C for T1, 300 °C for T2, 200 °C for T3, 135 °C for T4, 100 °C for T5, and 85 °C for T6. The required class must be selected against the ignition characteristics of the actual substance and the applicable rules; do not assume that a higher-looking number means higher allowable temperature.
Dust applications require particular attention to the protection marking and the dust properties, including whether the hazard is conductive, the equipment’s ingress protection, and permitted surface temperature. Gas and dust approvals may have different scopes. A marking suitable for a gas zone does not by itself establish suitability for a dust zone.
Request the current hazardous-area drawing or classification record for the exact inspection location. Confirm the zone or division, gas or dust group, temperature class, equipment protection level where relevant, ambient temperature range, and any site-specific restrictions. Also record the inspection task, access method, expected duration, and whether the instrument will be operated, stored, or charged inside the classified area.
If you want to learn more, please visit our website Coantec.
If the classification is missing, unclear, or inconsistent with the proposed work area, pause product selection and ask the site engineering or safety team to clarify it. A supplier can help interpret the information provided, but should not replace the site’s formal hazard assessment. Conditions can vary between locations within the same facility, so a facility-wide description may not be precise enough.
Compare the proposed equipment’s label and certificate documentation with the site requirements. Check that the approval covers the relevant hazardous material type, zone or division, gas or dust group, temperature class, ambient conditions, and protection concept. Pay attention to any conditions of use, such as limitations on accessories, cable connections, battery replacement, or maintenance.
For a borescope, assess the complete system rather than only the probe tip. The hand unit, display, power source, connectors, and any auxiliary lighting can all matter if they enter or operate in the classified area. Ask the supplier to identify which components are included in the approval and which must remain outside the hazardous location.
A compliant marking does not guarantee that a device suits the inspection job. Consider probe diameter and length, articulation, camera and illumination needs, viewing conditions, recording requirements, and access to the target. Confirm that the instrument can perform the work without unapproved modifications or accessories.
Also plan charging, storage, cleaning, and service. Unless the instrument documentation specifically permits it, do not charge or open equipment in a classified area. Define where the device will be inspected and maintained, who is authorized to perform those tasks, and how it will be transported between safe and hazardous locations.
| Information to confirm | Why it matters |
|---|---|
| Area classification and governing jurisdiction | Establishes the system and requirements against which the instrument must be checked. |
| Gas or dust hazard, group, and temperature class | Helps verify that the equipment marking is suitable for the substances and ignition limits involved. |
| Certification documents and exact configuration | Shows which components and operating conditions are covered by the approval. |
| Probe dimensions, articulation, lighting, and image functions | Determines whether the instrument can complete the inspection task effectively. |
| Ambient conditions, accessories, charging, and maintenance plan | Identifies operating limits and practical restrictions beyond the basic area marking. |
A useful supplier conversation begins with the site’s documented requirements and the inspection task. Provide the classification details, intended operating location, target dimensions, and any limits on cables, batteries, or accessories. Ask the supplier to state which product configuration is being proposed and to provide the relevant certification documentation for your technical team to review.
At Coantec, we can review the application information you provide and help identify the product details that should be checked for a borescope evaluation. Final approval for use must be based on the instrument’s applicable documentation and the requirements of the site and jurisdiction. If you do not yet have a confirmed area classification, resolve that point with your site’s qualified personnel before placing an order.
The right explosion-proof equipment is the equipment whose documented protection matches the classified area and whose configuration can perform the inspection safely and practically. Start with the site classification, confirm the substance group and temperature requirements, then verify the approval scope for the complete borescope system and its operating conditions. Your next step is to gather the classification record and inspection specifications, then share them with your engineering team and supplier for a documented review.
For more information, please visit Explosion-Proof Equipment Selection: Understanding Area Classification Needs.